BR-130W CO2 laser power supply
Feature
1.The 130W CO2 power supply has RED TEST button to easily figure out CO2 power supplies or CO2 laser tube's failure. It is very easy and simple to remove trouble.
2.Input analog signal(0~5V) or PWM is used to control the output laser power on this 130W CO2 power supply
3.The 220/110V CO2 power supply's control is applicable to high/low level signal. TTL level is to control the on/off of the laser power with a protective switch to check water-flow and ventilation.
4.The 130W CO2 power supply can match with EFR,Yongli,SPT, Weiju and other factories'160-165cm 130W sealed glass type CO2 laser tube. The 220/110V CO2 power supply uses zero-current half-bridge soft-switch circuit to make sure the CO2 power supply on laser cutter has high efficiency and fast response speed.
5.Each CO2 power supply on laser cutter before selling will go through the aging check:
(1) sustain 10 hours at temperature 60 Degrees Celsius under full-load condition;
(2) 500 times on/off check for 7 seconds.
6. The 220/110V CO2 power supply has H/L/P/G/IN/5V control signal port,The upper cover and bottom shell are aluminum shell is galvanized sheet.
7.The CO2 power supply on laser cutter is well grounded, which can ensure the safety of operators. At the same time, the 220/110v CO2 power supply also has an open circuit protection function, which allows the CO2 power supply on laser cutter to work for a short time in the open circuit state.
8.This130W CO2 power supply is equipped with two cooling fans. Better heat dissipation can protect the internal electronic components of this power supply
9.The 130W CO2 power supply can use an external LCD module. It can display common fault codes, output current and working status. It is helpful for operators to understand the working state of 220/110V CO2 power supply and solve problems quickly. In addition, the output current can also be changed by the rotating potentiometer of the LCD module.
Specification
Input
|
Input voltage
|
AC220V±10% (AC110V specified while order)
|
AC frequency
|
47~440HZ
|
Maximum input power
|
970W
|
Maximum input current
|
4.3A
|
Output
|
Maximum output voltage
|
40KV
|
Maximum output current
|
36mA
(depending on the laser tubes of different manufacturers)
|
Efficiency
|
More than 90% (Full load)
|
Response speed
|
Not more than 1ms
|
Control lnterace
|
TTL multilevel switching control,effective level can be high and low selection (see control wining diagram)
|
Insulation
|
lnput-output
|
AC 1500V 1 minutes not more than 10mA
|
lnput-shell
|
AC 1500V 1 minutes not more than10mA
|
Output-shell
|
Connection
|
Open Circuit Protection
|
Can be short circuit (requires a good grounding shell,while avoiding the positive electrode and the shell between the arc)
|
Environmental Requested
|
Working temperature
|
-10℃~50℃
|
Storage of temperature
|
-20℃~75℃
|
Relative Humidity
|
Maximum 85%RH (non-condensing)
|
Altitude
|
100,000 feet of work
200,000 feet of storage,dose not work
|
Cooling methods
|
Forced air cooling (fan cooling)
|
Dimensions (LxWxH)
|
335mmx205mmx100mm
|